How to Thaw a Frozen Condensate Pipe: Step-By-Step

Learn how to thaw a frozen condensate pipe, prevent future freezes, and when to call a professional to get your heating back up and running.

As temperatures drop, the last thing anyone wants is a cold home caused by a broken boiler. A frozen condensate pipe is often the cause of boilers that suddenly shut down during the winter months.

Fortunately, this issue can be resolved at home with a few DIY methods.

In this guide, we’ll show you how to identify if a frozen condensate pipe is behind your heating issues and walk you through the steps to resolve it safely. We’ll also share preventative tips to reduce the chances of this happening again and advise when it’s best to call in a professional for help.

Keep reading to discover:

What is a condensate pipe?

How can I tell if the condensate pipe is frozen?

How to thaw a frozen condensate pipe: step-by-step guide

Minimising future risks of a frozen condensate pipe

When to call in a JustFix professional

FAQs about frozen condensate pipes

What is a condensate pipe?

A condensate pipe is a plastic pipe that connects to condensing boilers. It carries away the excess water created during the heating process.

A condensing pipe runs from the boiler to an external drain; seeing water flow through it shows your boiler is working correctly.

How can I tell if the condensate pipe is frozen?

When a condensate pipe freezes, it often disrupts the entire heating system, causing your boiler to shut down. Here are a few telltale signs that a frozen condensate pipe is the culprit behind your boiler issues:

  • No heating or hot water: Your boiler suddenly stops producing heat or hot water, and restarting it doesn’t help.
  • Gurgling noises: You may hear unusual gurgling or bubbling sounds from the boiler or pipes. This is the noise of trapped water struggling to pass through the frozen section.
  • Visible ice or frost: If you can see ice or frost on the condensate pipe outside your home, it’s a sign that the pipe is frozen.
  • Boiler error codes: Boilers display error codes for various problems, including when the condensate pipe is frozen. For example, a Vaillant boiler shows error codes F28 and F29, and a Baxi boiler shows codes E133 or E28. The following boiler code guides can help you diagnose boiler issues: Worcester Bosch Boiler Error Codes, Vaillant Boiler Error Codes, Baxi Boiler Error Codes, Ideal Boiler Error Codes.

If you notice any of these symptoms, your condensate pipe has likely frozen. The good news is it’s an easy fix. Just follow our step-by-step guide to thaw your condensate pipe and restore your heating system to normal.

How to thaw a frozen condensate pipe: step-by-step guide

To thaw a frozen condensate pipe, just follow these three simple steps.

1.   Locate the frozen section of the pipe

Firstly, identify the condensate pipe and find the frozen section. The pipe is usually white or grey and made of plastic, leading from your boiler to a drain. It’s most vulnerable to freezing outside, where it’s exposed to the elements. The frozen section may feel cold and have visible frost or ice.

2.   Thaw the pipe

There are a few methods for safely thawing a frozen pipe. Try the following solutions:

  • Wet a cloth with warm water or fill a hot water bottle with boiling water. Then, hold the item to the pipe to gradually thaw the ice.
  • Gently pour warm (not boiling) water over the frozen section of the pipe. Using boiling water can cause the plastic to crack and lead to leaks. Be aware that this water may freeze on the ground and make the surrounding area slippery.
  • Use a hairdryer on a low-medium setting to direct warm air onto the pipe. Move the hairdryer evenly along the frozen section to ensure consistent thawing. Keep it at a safe distance to prevent overheating.

3.   Reset the boiler

Once you’ve thawed the pipe, inspect it for cracks or leaks. If your boiler looks intact, it should be safe to restart. Some boilers will automatically reset, but if you don’t know how to restart yours, read our How to Reset Your Boiler guide or check the manual for instructions.

If your boiler won’t turn on after thawing the pipe, or if you’ve noticed damage to the pipe following an attempt to thaw it, it’s probably best to call in a professional.

shutterstock_2482563549-min

​​When you book with JustFix, we’ll match you with a local heating and gas engineer to get your heating system back in working order. Our Fixers can arrive in as little as 30 minutes, so you’ll be warm and toasty again in no time!

Minimising future risks of a frozen condensate pipe

Once you’ve thawed the condensate pipe, there are some preventative measures you can take to minimise the risk of it freezing again. Here are some ways to prevent a frozen condensate pipe:

  • Insulate the pipe: Use foam pipe insulation to cover the outside section of your condensate pipe. This helps keep the pipe warmer and prevents it from freezing.
  • Keep the heating on: Keeping your heating running overnight at a low temperature will keep the pipe warm.
  • Reroute the pipe: Rerouting the pipe so that it primarily runs through the inside of your house significantly reduces the chances of it freezing, as most of it will not be exposed to the cold.
  • Adjust the pipe angle: Changing the angle of the condensate pipe can improve the flow of water and help prevent it from freezing solid.
  • Use a larger diameter pipe: Swapping your condensate pipe out for a wider model can be helpful if you live somewhere especially cold, as the larger diameter pipe will be less likely to freeze fully.

For more prevention methods, check out our detailed guide: How to Avoid Frozen Pipes.

When to call in a JustFix professional

A frozen condensate pipe can usually be fixed using a DIY approach. However, sometimes, it might be best to call in a professional. You should contact a Gas Safe-registered heating and gas engineer if:

  • Your heating system does not restart after having thawed the frozen condensate pipe
  • You notice any damage to the pipe after thawing it
  • Your condensate pipe repeatedly freezes despite having taken preventative measures
  • You want to reroute your condensate pipe to prevent exposure to the cold

Our accredited engineers are experienced in handling all sorts of condensate pipe, boiler, and heating system issues. Simply use the JustFix app or website to share a few details about the job, and we’ll connect you with an accredited Fixer in your local area.

shutterstock_2342106287-min

Plus, we offer a fixed hourly rate and a 12-month guarantee on all work undertaken, providing you peace of mind during the colder months.

FAQs about frozen condensate pipes

Can I pour boiling water over a frozen condensate pipe?

No, pouring boiling water over a frozen condensate pipe can cause it to crack or even melt, leading to further damage, like severe leaks. As a result, you should only use warm water to thaw a frozen condensate pipe.

What should I do if my boiler doesn’t restart after thawing the pipe?

If your boiler doesn’t restart, check for error codes or signs of damage. If you can’t identify the issue, contact a professional JustFix heating and gas engineer for help.