Vaillant Boiler Error Codes

Discover common Vaillant boiler error codes and their meanings. Get quick fixes for issues with heating and hot water systems for efficient troubleshooting.

Vaillant boilers are known for their reliability and efficiency, but like any complex system, they can occasionally run into issues. When problems arise, the boiler will display specific error codes that help identify the fault. Understanding these codes is crucial for diagnosing and resolving issues quickly, whether you're a homeowner or a professional engineer.

These error codes can indicate a range of issues, from problems with the gas supply, safety switches, or temperature sensors, to more specific faults like defective condensate pumps, ignition failures, or incorrect settings.

This guide covers a comprehensive list of Vaillant boiler error codes across various models, such as the EcoTEC Plus, Turbomax Plus, and Ecomax Pro. Each code points to a particular issue, whether it's related to the gas flow pressure, flue gas temperature, or mass flow sensor.

By familiarising yourself with these error codes, you can better understand the problem, decide on the appropriate fix, and maintain your boiler's performance, ensuring a safe and efficient operation for years to come.

Vaillant boiler error codes by model

  1. Vaillant Turbomax Plus 824/828E
  2. Vaillant EcoMax Pro 18/28E
  3. Vaillant Ecomax Pro 828E
  4. Vaillant EcoTEC 65kW error codes
  5. Vaillant EcoTEC Pro / EcoTEC Plus boiler fault codes
  6. Vaillant EcoTEC Pro / EcoTEC Plus cont.
  7. Vaillant EcoTEC Plus Regular Gas Boiler
  8. Vaillant EcoTEC Plus Gas Boiler
  9. Vaillant EcoTEC Gas Boiler error codes
  10. Vaillant Error Codes F28 and F29

When to call in a JustFix professional

 

Vaillant boiler error codes by model

Vaillant boilers come in various models, each with its own set of error codes. These codes help identify issues ranging from gas supply problems to faulty temperature sensors.

Let’s break down these codes by model so you can quickly find the information relevant to your boiler.

1.    Vaillant Turbomax Plus 824/828E

The Vaillant Turbomax Plus 824/828E is a widely used model known for its reliability. However, like any boiler, it can encounter issues. Below is a table of the most common error codes for this model.

Fault Code

Possible Cause

Meaning

F.00

NTC Faults

Flow NTC (Negative Temperature Coefficient Thermostat) cable is either defective or broken and needs to be replaced.

F.01

NTC Faults     

Similar to F.00, this involves the feed temperature sensor and indicates a faulty connection or open circuit.

F.10

NTC Faults     

This refers to a short circuit in the feed temperature sensor.

F.20

Overheating

Your boiler has exceeded the maximum temperature and needs to cool down.

F.22

Dry Fire, Low Water

There’s either no water in your system, a defective pump, or the pump lead is defective.

F.28

Ignition Problem

This could be due to insufficient gas, a defective electrode, ignition lead, or an electronic ignitor.

F.29

Flame Extinguished

The flame or pilot light has gone out. Check your flue duct or gas supply.

F.60

Gas Valve Control Fault

The cable loom connected to your gas valve might have short-circuited. Alternatively, you could have a defective gas valve assembly or electronic control system.

F.63

EEPROM Error

This indicates an electronic fault within your system.

2.    Vaillant EcoMax Pro 18/28E

The Vaillant EcoMax Pro series is another popular model, especially in larger homes. Here are its common error codes.

Fault Code​

Possible Cause

Meaning

F.1

Gas Supply Issue

This could be due to a lack of gas, a fault with the ignition or flue, or you may need to adjust the gas valve or replace a defective electrode lead.

F.4

Ignition Fault

The boiler failed to ignite.

F.5

Overheating

The system has overheated.

F.6

NTC Fault

Your flow NTC has developed a fault.

F.17

Polarity Issue

Check the polarity of your system.

F.24

Pump Failure

The pump could have failed, overrun, or there could be an issue with the airlock.

3.    Vaillant Ecomax Pro 828E

For larger properties or commercial applications, the Vaillant EcoTEC 65kW is a powerhouse. Below are some common error codes for this model.

Fault Code

Possible Cause

Meaning

S.O

Heating Issue

No heat demand.

S.1

Fan Start-Up Error

The fan failed to start up.

S.3

Ignition Problem

The boiler failed to ignite.

S.4

Burner On Error

There was an issue with the burner igniting.

S.31

No Heat Demand

This typically occurs in summer operating mode.

S.34

Frost Protection Error

An error occurred during the frost protection mode.

S.22

Pump Flow Error

The pump is not circulating water as it should.

4.    Vaillant EcoTEC 65kW error codes

The EcoTEC Pro and Plus models are among the most popular Vaillant boilers. They are efficient and reliable but can still encounter issues. Here’s a breakdown of the error codes for these models.

Fault Code

Possible Cause

Meaning

F.00 / F.0

Flow Temperature Sensor Interruption

The flow temperature sensor is not functioning correctly.

F.10

Flow NTC Short Circuit

The flow NTC has a short circuit.

F.20

Safety Switch Off

The temperature limiter has been triggered.

F.22

Low Water Pressure

The system has low water pressure.

F.23

Temperature Difference Too Great

The temperature difference between flow and return is too large.

F.25

Flue Gas Temperature Too High

The temperature of the flue gases is too high.

F.28

Ignition Unsuccessful

The boiler failed to ignite.

F.29

Re-Ignition Unsuccessful

The boiler failed to re-ignite after the flame went out.

F.61

Gas Valve Regulation Error

The gas valve is not regulating the gas flow correctly.

F.62

Gas Valve Switch Off Delay

The gas valve is not closing as quickly as it should.

F.73

Water Pressure Sensor Signal Too Low

The signal from the water pressure sensor indicates low pressure.

F.75

No Pressure Change Detection

The system did not detect a change in pressure when the pump started.

5.    Vaillant EcoTEC Pro / EcoTEC Plus boiler fault codes

For those with the EcoTEC Plus Regular Gas Boiler, the following error codes are essential to know.

Fault Code

Possible Cause

Meaning

S.20

Warmstart Demand

The boiler is waiting for a heat demand.

S.21

Fan Running

The fan is running as expected.

S.22

Pump Running

The pump is running as expected.

S.23

Ignition Sequence

The boiler is in the ignition sequence.

S.28

Anti-Cycling Mode

The boiler is in anti-cycling mode, which prevents it from repeatedly turning on and off.

S.34

Anti-Frost Mode Active

The boiler is in anti-frost mode.

S.53

Modulation F Block Function

The boiler is in a waiting period due to water shortage.

S.96

Return Sensor Error

There’s an issue with the return temperature sensor.

6.    Vaillant EcoTEC Pro / EcoTEC Plus cont.

 

Fault Code

Possible Cause

Meaning

S.00

Heating mode error – no heat demand

No heat demand detected in heating mode

S.01

Heating mode fan start-up

The fan has started up in heating mode

S.02

Heating mode error – water pump running

Error with the water pump in heating mode

S.03

Heating mode – ignition sequence error

Problem with the ignition sequence in heating mode

S.04

Heating mode – burner ignited

Burner has successfully ignited in heating mode

S.06

Heating mode – fan overrun error

Fan is running longer than expected in heating mode

S.07

Heating mode – pump overrun error

Water pump is running longer than expected in heating mode

S.08

Heating remaining cut off time xx minutes

Time remaining until heating mode shuts off

S.10

Hot water demand via impeller sensor

Hot water demand detected via the impeller sensor

S.11

DHW mode fan start-up error

Error with fan start-up in Domestic Hot Water (DHW) mode

S.13

DHW mode ignition error

Issue with ignition in DHW mode

S.14

Hot water demand via fan sensor error

Hot water demand detected via fan sensor error

S.15

DHW mode pump and fan overrun

Both pump and fan running longer than expected in DHW mode

S.16

DHW mode – fan overrun error

Fan is running longer than expected in DHW mode

S.17

DHW mode – pump overrun error

Pump is running longer than expected in DHW mode

S.20

DHW mode – burner on error

Burner issue detected in DHW mode

S.21

DHW mode – fan start-up error

Error with fan start-up in DHW mode

S.22

DHW demand – error pump running

Pump running error detected during DHW demand

S.23

DHW ignition error

Ignition issue in DHW mode

S.24

DHW mode – burner error

Burner error detected in DHW mode

S.25

DHW mode – pump or fan overrun error

Either pump or fan running longer than expected in DHW mode

S.26

DHW mode – fan overrun

Fan running longer than expected in DHW mode

S.27

DHW mode – pump overrun

Pump running longer than expected in DHW mode

S.28

Hot water burner anti-cycling time

Anti-cycling time for the hot water burner

S.30

Room thermostat is blocking heating mode

Heating mode is blocked by the room thermostat

S.31

No heat demand boiler in summer operating mode

No heat demand as the boiler is in summer mode

S.32

Waiting period because of fan speed deviation

Delay due to fan speed deviation

S.34

Heating mode frost protection error

Error in frost protection during heating mode

S.39

Burner off contact has been triggered

Burner shut off due to thermostat or condensate pump issue

S.40

Comfort safety mode active

Boiler in safety mode to ensure comfort

S.41

Water pressure > 2.8 bar

Water pressure exceeds 2.8 bar

S.42

Flue non-return flap return signal blocks burner operation

Flue flap issue blocking burner operation

S.46

Comfort safety mode flame loss at minimum load

Flame loss in safety mode at minimum load

S.53

Boiler is in waiting period of modulation function due to water shortage

Boiler waiting due to water shortage affecting modulation

S.54

Boiler is in waiting period of operation, blocking function as a result

Operation blocked due to waiting period

S.57

Waiting period comfort safety mode

Boiler in waiting period due to safety mode

S.58

Modulation limitation due to noise/wind error

Modulation limited due to noise or wind error

S.61

Gas family check unsuccessful

Failed gas family check

7.    Vaillant EcoTEC Plus Regular Gas Boiler

The Vaillant EcoTEC Plus Regular Gas Boiler combines robust performance with energy efficiency, ideal for homes that require a dependable and consistent heating source. For any operational issues, check the error codes below to help identify and resolve common problems with this model.

Fault Code

Possible Cause

Meaning

S.20

Warnstar demand

Demand signal error for Warnstar system

S.21

Fan running

Fan is operating

S.22

Pump running

Pump is operating

S.23

Ignition sequence

Issue with the ignition sequence

S.24

Burner ignited

Burner has ignited successfully

S.25

Fan and water pump running

Both fan and water pump are operating

S.26

Fan overrun

Fan running longer than expected

S.27

Pump overrun

Pump running longer than expected

S.28

Anti-cycling mode

Mode to prevent rapid cycling of the burner

S.30

No heating demand from external controls

No heating demand detected from external controls

S.31

Central heating thermostat knob turned off

Thermostat knob is set to off

S.32

Heat exchanger antifreeze active due to high fan speed variation

Anti-freeze mode activated due to fan speed variation

S.34

Anti-frost mode is active

Anti-frost protection mode is active

S.36

Not heating demand from low voltage

Low voltage issue affecting heating demand

S.41

Water pressure greater than 2.9 bar

Water pressure exceeds 2.9 bar

S.42

Response from accessory module or defective condensate pump blocking burner operation

Accessory module or condensate pump issue blocking burner

S.53

Appliance in waiting period of block operation function due to water shortage

Waiting period due to water shortage affecting block operation

S.54

Appliance in waiting period of block operation due to water shortage

Waiting period due to water shortage affecting block operation

S.96

Return sensor error

Error with the return sensor

S.98

Flow return sensor check is running demand is blocked

Flow return sensor check in progress with blocked demand

8.    Vaillant EcoTEC Plus Gas Boiler

The Vaillant EcoTEC Plus Gas Boiler is known for its high efficiency and reliable heating performance, suited for various home heating needs. If you face any difficulties with your EcoTEC Plus, the error codes provided here will aid in diagnosing and fixing common issues effectively.

Fault Code

Possible Cause

Meaning

P.00

Heating circuit and hot water circuit are purged

The circuits are being purged.

P.01

Maximum load test program error

Error during the maximum load test program.

P.02

Minimum load test program

Error during the minimum load test program.

P.06

Filling mode test program

Error during the filling mode test program.

9.    Vaillant EcoTEC Gas Boiler error codes

Designed to offer excellent heating efficiency, the Vaillant EcoTEC Gas Boiler is a versatile choice for residential heating. For any operational concerns, consult the following error codes to help pinpoint and resolve issues that may arise with this model.

Fault Code

Possible Cause

Meaning

D.0

Heating part load error

Error with heating part load.

D.1

Water pump overrun – time for heat mode

The water pump is running longer than necessary.

D.2

Max burner anti-cycling period at 20°C flow temperature

Burner anti-cycling period exceeded at 20°C.

D.3

Hot water flow temperature reading

Reading issue with the hot water flow temperature.

D.4

Current temperature for warm stat sensor

Issue with the warm stat sensor temperature reading.

D.5

Set value of flow temperature or target value of return

Incorrect set value for flow or return temperature.

D.7

Warm start temperature target value

Issue with the warm start temperature target.

D.8

External controls heat demand

Problem with heat demand from external controls.

D.9

Flow target temperature from external analogue regulator terminal

Incorrect flow target temperature from external regulator.

D.10

Status internal heating pump error

Error with the internal heating pump status.

D.11

Status external heating pump error

Error with the external heating pump status.

D.12

Cylinder charging pump via accessory module

Issue with the cylinder charging pump.

D.13

Hot water circulation pump

Problem with the hot water circulation pump.

10. Vaillant Error Codes F28 and F29

If your Vaillant boiler is showing either error code F28 or F29, then the condensate pipe has frozen and needs to be thawed.

This issue can occur during the colder months as the pipe runs outside but can be resolved fairly easily without the need for an engineer, as the pipe just needs to be thawed out.

When to call in a JustFix professional

While some boiler error codes can be resolved with basic troubleshooting, there are times when it’s essential to call in a professional. If you’ve attempted to fix an error code but it keeps reappearing, or if the issue involves critical components like the gas valve, flue gas temperature, or safety switches, it’s time to contact a Gas Safe registered engineer at JustFix.

At JustFix, we’re committed to delivering expert service at competitive prices. Whether you’re facing persistent error codes, suspect a fault in the primary heat exchanger, or simply want the assurance of professional intervention, our nationwide team of skilled engineers is ready to help.

Book online, and we’ll connect you with a qualified local expert who can accurately diagnose and resolve your boiler faults—restoring your heating system’s performance at a time that suits you.

For more guidance on other common issues, explore our blog, where we cover topics such as whether a leaking overflow pipe is dangerous and why your boiler is making a banging noise.

The JustFix App is designed to make your life easier and provide solutions to your home.
Download the JustFix app today for a fast, easy and convenient service.