Ideal Boiler Error Codes

Find comprehensive information on Ideal boiler error codes, including common faults and troubleshooting tips to help you resolve issues with your Ideal boiler.

Ideal boilers are known for their reliability and efficiency, making them a popular choice for homeowners across the UK. However, like all appliances, they can occasionally experience faults. When this happens, Ideal boilers display error codes that help diagnose the problem quickly.Understanding these codes can save you time and money by allowing you to troubleshoot issues or communicate more effectively with a professional engineer.

This guide provides an overview of the most common Ideal boiler faults, from low boiler pressure to ignition faults, to help you identify and address any issues you might encounter.

Common Ideal boiler error codes

Ideal boiler error codes by model

Ideal Logic Max System / Logic Plus System Boiler error codes

Ideal Logic Max / Logic Plus Regular Boiler error codes

Ideal Logic Max Plus Combi Boiler faults

Ideal Vogue Boiler fault codes

Ideal Boiler error descriptions

When to call in a JustFix professional

 

Common Ideal boiler error codes

Fault Code

System Behaviour

C0

Boiler chip card (BCC) activation fault

C2

Boiler chip card (BCC) fault

F1

Low water pressure

F2

Flame loss

F3

Fan fault

F4

Flow thermistor fault

F5

Return thermistor fault

F6

Outside sensor failure

F7

Low mains voltage

F9

Unconfigured printed circuit board (PCB)

L1

Flow temperature overheat or no water flow

L2

Flame loss

L5

5 boiler resets in 15 minutes

L6

False flame lockout

0

The boiler is in standby mode, awaiting either a central heating or hot water demand

C

The boiler has a call for central heating but has reached the set temperature or is operating in central heating mode

D

The boiler has a call for hot water but has reached the set temperature

d

The boiler is operating in hot water mode

F

The boiler is operating in frost mode

Ideal boiler error codes by model

Ideal Logic Max System / Logic Plus System Boiler error codes

The Ideal Logic Max and Logic Plus System boilers are designed for reliability and performance. However, like any boiler, they can encounter issues that trigger error codes. Here are the key fault codes for these models:

Error Code

System Behaviour

L1

Flow temperature overheat lockout or no water flow lockout

L2

Ignition lockout

LC

Turn power off and on

L6

False flame lockout

F1

Low water pressure

F2, FN or LN

Flame loss

F3

Fan fault

L4 or F4

Control / no flow thermistor fault

L5 or F5

Return thermistor fault

F6

Outside sensor fault

F7

Low mains voltage. Contact electricity provider.

F9, L9, F8 or L8

Printed circuit board (PCB) unconfigured or fault

FU

Diff greater than 50°C - check isolation valves are open

Ideal Logic Max / Logic Plus Regular Boiler error codes

The Ideal Logic Max and Logic Plus Regular boilers can also encounter certain faults. Here’s a list of common error codes:

Fault Description

System Behaviour

L1

Flow temperature overheat lockout or no water flow lockout

L2

Ignition lockout

LC

5 restarts within 15 minutes

L6

False flame lockout

FA

Flow return reversed

FD

No water flow

F2 or FN or LN

Flame loss

F3

Fan fault

L4 or F4

Control / no flow thermistor fault

L5 or F5

Return thermistor fault

F6

Outside sensor fault

F7

Low mains voltage. Contact electricity provider.

F9, L9, F8 or L8

Printed circuit board (PCB) unconfigured or fault

FU

Diff greater than 50°C - check isolation valves are open

Ideal Logic Max Plus Combi Boiler faults

The Ideal Logic Max Plus Combi boiler is a high-efficiency model that may have the following faults:

Fault Description

System Behaviour

Overheat lockout

Bleed radiators, refill system to 1.0 bar, check that radiator and boiler valves are open. Reset boiler. If fault continues, book an engineer.

Ignition lockout

Check gas appliances work and restart boiler.

Too many restarts

5 starts within 15 minutes. Turn power on and off.

Flame on before gas on

False flame lockout

Water pressure

With boiler off and system cold, fill system to 1.0 bar and bleed radiators. If fault continues, contact an installer.

Ideal Vogue Boiler fault codes

The Ideal Vogue boiler is another robust model, though it too can encounter errors. Here are some key fault codes:

Fault Description

System Behaviour

Too many resets

5 restarts within 15 minutes

Flame on before gas valve on

Flame on before gas valve is on

Flow thermistor fault

Flow thermistor error

Low mains voltage

Less than 185V to boiler. Check voltage at boiler mains input. If mains voltage is okay, the pump needs replacing.

Low water pressure

Low water pressure

Flow return reversed

Check if the flow thermistor is correctly clipped to pipe. Replace if necessary.

Printed circuit board (PCB) recently replaced

Reset boiler

Pump rotor blocked

Unblock pump

Flow temperature set point cannot be increased to 80°C

Check flow and return thermistors are securely clamped to pipes.

Ideal Boiler error descriptions

In addition to specific model faults, some general issues can occur across multiple Ideal boiler models. Here are a few more common error descriptions:

Fault Description

Cause

Thermal fuse lockout

Reset the boiler.

Too many boiler resets

5 resets within 15 minutes. Turn power off and on.

Printed circuit board (PCB) replaced incorrectly

Ensure the boiler chip card (BCC) is fitted correctly.

Low mains voltage

Less than 160V to the boiler. Contact the electricity provider.

Low water pressure

Increase system pressure to 1.5 bar.

Flow/Return reversed

Check if the flow thermistor is correctly clipped to the pipe. Replace the flow thermistor if necessary.

Pump rotor blocked

Unblock the pump.

Flow temperature set point cannot be increased to 80°C

Ensure the flow temperature is not limited within installer mode.

Pump runs during the night

Ensure the system frost protection temperature set point isn’t set too high.

Gas pressure < 18mBar

Check the gas supply and rectify the fault.

No connection to primary printed circuit board (PCB)

Unblock the pump.

Flame loss

Check the detection electrode and associated harness for continuity, visual condition, and position. Check if the condensate pipe is blocked.

Printed circuit board (PCB) replaced

Reset the boiler.

When to call in a JustFix professional

While some boiler error codes can be resolved with basic troubleshooting, there are times when it’s essential to call in a professional. If you’ve attempted to fix an error code but it keeps reappearing, or if the issue involves critical components like the gas valve, flue gas temperature, or safety switches, it’s time to contact a Gas Safe registered engineer at JustFix.

At JustFix, we’re committed to delivering expert service at competitive prices. Whether you’re facing persistent error codes, suspect a fault in the primary heat exchanger, or simply want the assurance of professional intervention, our nationwide team of skilled engineers is ready to help.

Book online, and we’ll connect you with a qualified local expert who can accurately diagnose and resolve your boiler faults—restoring your heating system’s performance at a time that suits you.

For more guidance on other common issues, explore our blog, where we cover topics such as boiler efficiency ratings and why your boiler is making a banging noise.

The JustFix App is designed to make your life easier and provide solutions to your home.
Download the JustFix app today for a fast, easy and convenient service.